Skip to content

GDSII

GDSII (Graphic Data System II) is the de-facto industry standard for IC mask layout data exchange. Originally developed by Calma Company in the 1970s, it uses a binary format with hierarchical cell structures.

Format Summary

Property Value
Extensions .gds, .gdsii
Encoding Binary
Import
Export
License Basic
Hierarchy Full cell hierarchy with SREFs and AREFs
Layers Numeric layers (0–65535) with datatypes (0–65535)

Import Options

Option Description Default
Ignore text elements Skip TEXT records during import Off
Font size Size for imported text elements Auto
Font size units Units for the font size value Micron

Supported Features

  • All GDSII record types (BOUNDARY, PATH, SREF, AREF, TEXT, NODE, BOX)
  • Full hierarchy preservation with cell references
  • Layer numbers and datatypes
  • Text labels with positioning
  • Path elements with end treatments (flush, half-round, extended)
  • Array references (AREF) with row/column expansion
  • Custom properties and attributes

Export Options

Option Description Default
Database units Internal coordinate resolution 1 nm
User units Display units written to the GDSII header 1 µm
Precision Coordinate resolution 1 nm
Flatten hierarchy Expand all cell references Off
Explode text Convert text to polygons Off
Split polygons Maximum vertices per polygon (GDSII limit: 8191) 8191
Pad to boundary Pad output to even byte boundary On

Common Workflows

GDSII → DXF

Standard IC-to-mechanical conversion. Set DXF output units to match your target CAD system (typically millimeters or inches).

GDSII → Gerber

Convert IC mask data to photoplotter format for PCB-style fabrication.

GDSII → CIF

Convert to the human-readable CIF format for academic or legacy tool chains.

GDSII → GDS-TXT

Produce a text representation for manual inspection, scripting, or diff.

Technical Notes

  • GDSII coordinates are stored as 32-bit integers in database units
  • Database unit resolution is typically 1 nm (nanometer)
  • Maximum polygon vertex count per element is 8191
  • Layer numbers range from 0 to 65535; datatypes from 0 to 65535
  • File size limit: none (streaming I/O)
  • Timestamps in GDSII headers are preserved during round-trip conversion

CLI / Command-File Options

These option keys can be used on the command line or in command files.

Import

Key Type Description
GdsInIgnoreText flag Ignore text elements
GdsInIgnoreDataTypes flag Ignore GDSII data types
GdsInFontSizeUnits int Font size unit enum (see Units)
GdsInFontSizeValue float Font size value

Export

Key Type Description
GdsOutDbScalingUnits int Database scaling unit enum (see Units); default: Nanometer
GdsOutDbScalingValue float Database scaling value
GdsOutFontSizeValue float Export font size multiplier
GdsOutPad flag Zero-pad output records